Quick Answer

For construction sites, typical generator sizes range from 20-500 kVA. The critical sizing factor is mobile requirements, welder and crane inrush, variable loads. Always calculate both running kW and starting kVA, apply appropriate diversity factors, and add 20% growth margin for future expansion.

Generator Sizing for Construction Sites — Complete Guide (2026)

Proper generator sizing for construction sites is essential for reliable power. This comprehensive guide covers everything you need to know to select the right generator size.

Power Requirements for Construction Sites

Construction Sites applications have specific power requirements that must be understood before sizing. The load profile typically includes a mix of resistive and inductive loads with varying duty cycles.

Sizing Methodology for Construction Sites

Step 1: Complete a detailed load survey. Step 2: Separate running loads from starting loads. Step 3: Calculate total running kW with diversity factor. Step 4: Add the largest motor starting kVA. Step 5: Apply environmental de-rating factors. Step 6: Add growth margin and select standard size.

ParameterValueNotes
ApplicationConstruction SitesSpecific sizing considerations apply
Typical Size20-500 kVAVaries with specific requirements
Diversity Factor0.6-0.9Depends on load coincidence
Growth Margin20%Standard for new installations
Phase1 or 3Based on load types
Frequency50 or 60 HzRegion dependent
Load Component% of TotalStarting Factor
Motor Loads40-60%3-7x
Resistive Loads20-30%1x
Lighting10-20%1x
Electronics/IT5-15%1-2x

Key Takeaways

Summary

Proper generator sizing is the foundation of reliable backup power. By calculating both steady-state running loads and transient starting requirements, applying appropriate diversity factors, and accounting for environmental conditions, you ensure the generator delivers reliable power without wasteful oversizing. A correctly sized generator provides the right balance of capability, efficiency, and cost.

Frequently Asked Questions

100% load continuously?
Standby: 70-80% avg. Prime: 70% avg. Continuous: 100% 24/7.
3x motor starting rule?
Induction motors draw 3-7x running current at start. Use 3x minimum for sizing.
Altitude impact on sizing?
At 2000m, NA engine loses 15-20%. Turbocharged less affected. Apply de-rate tables.
What is load shedding?
Prioritizes critical loads when capacity is limited. Non-essentials auto-disconnect.
De-rating for temperature?
Standard generators rated at 40°C. Each 1°C above de-rates 0.5-1%. At 50°C: lose 5-10%.
Generator growth margin?
Add 10-25% to calculated size. Industrial: 20% minimum. Data center: 25% minimum.
Data center generator sizing?
IT load + cooling + UPS losses. 0.9 diversity, 25% growth. 500kW IT needs 800-1000 kVA.
Undersized generator consequences?
Voltage/frequency dips, overheating, wet-stacking, premature wear, electronics damage.
1-phase vs 3-phase sizing?
1-phase for residential. 3-phase for industrial/motors. Keep imbalance <30%.
Resistive vs inductive load sizing?
Resistive: 1x running = sizing. Inductive: must add starting surge of 3-7x running.
Prime vs standby sizing?
Prime = continuous with variable load. Standby = emergency backup only. Size per application.
Generator for commercial building?
50-200 kW typical. Include elevator, server room, HVAC, lighting. 0.8 diversity.
kW vs kVA difference?
kW is real power; kVA is apparent power. 100 kVA delivers ~80 kW at 0.8 PF.
What generator size for a house?
8-20 kW for essentials. Add HVAC inrush (3-7x running). Whole-house: 20-30 kW.
What is diversity factor?
The ratio of actual simultaneous load to total connected load. Typically 0.6-0.9 depending on application.